HanYuan Dispenser
High-Power EV Charging — Built Around Your Space, Ready for Every Driver.
High-Power, Multi-Standard Charging
Delivering up to 300 A with air-cooled cables or 600 A with liquid-cooled, support for CCS1, CCS2, GB/T, and NACS.
Compact & Flexible Installation
Our dispenser offers exceptional placement flexibility, making it ideal for space-restricted environments such as underground car parks, parking halls, and wall-adjacent bays.
User-Friendly Design
A 10" HD touchscreen and integrated cable management system make every charging session intuitive and hassle-free — keeping drivers confident and coming back.
Commercial-Grade 10" HD Display
Minimize Friction, Maximize Utilization.
Deliver a premium site experience that reflects well on your business. Our 10″ HD touchscreen features an industrial-grade anti-glare display, ensuring pricing and instructions remain perfectly visible in any weather or lighting condition. This intuitive interface significantly reduces user errors and customer support calls, ensuring a seamless flow of traffic and maximizing the daily utilization rate of your charging assets.
360° Cable Management
Lower Maintenance Costs & Enhanced Site Safety
Protect your investment and reduce operational overhead. The integrated cable management system keeps heavy charging leads off the ground, dramatically reducing physical wear-and-tear and eliminating costly tripping hazards. With a full 360-degree reach, it accommodates any vehicle parking orientation without frustration, maximizing parking bay efficiency while keeping your facility looking clean, professional, and compliant.
High-Power, Multi-Standard Charging
One dispenser. Every EV on the road today.
With air-cooled cables delivering up to 300 A and liquid-cooled cables reaching 600 A, our dispenser scales to the demands of both passenger EVs and heavier commercial vehicles — without compromising charge speed.
Native support for CCS1, CCS2, GB/T, and NACS means a single unit is ready for virtually every EV on the market, today and as the standard landscape continues to evolve.
Designed for versatility, the dispenser supports CCS1, CCS2, GB/T, and NACS in a single unit — ready for mixed-use sites and high-density parking environments. Delivering up to 300 A, it handles the full range of everyday passenger EV charging needs without compromise. An optional emergency stop button is available for sites requiring additional safety compliance.
Built for maximum output, the liquid-cooled dispenser delivers up to 600 A — making it the ideal choice for ultra-fast charging of high-capacity EVs and commercial vehicles. The 10″ HD touchscreen and ADA-compliant height ensure an ergonomic experience for every driver, while the integrated cable management system keeps the charging area neat and hazard-free.
Application
Motorway Service Area
Public Charging Hubs
Fleet & Depot Charging
Specification
Natural cooling dispenser
| Output | |
| Charging Interfaces | 2*CCS1, 2*CCS2, 2*GBT, 1*CCS1+1*NACS |
| Output DC Voltage Range | 150-1000V DC |
| Maximum DC Current | 300A |
| Cable Lengths | 5m / 7.5m |
| Input | |
| DC Current | Up to 300A per DC circuit |
| DC Circuits from Power Cabinet | 1, 2 |
| AC Supply | Three-phase AC provided by Power Cabinet |
| Communication with Power Cabinet | Ethernet |
| Operating Conditions | |
| Operating Temperature | -30° to +50° |
| Altitude | < 2500m |
| Storage Temperature | -40° to +50° |
| Humidity | 10% - 95% relative (non-condensing) |
| Installation | Indoor and outdoor |
| Type of Installation | Floor mounted on foundation |
| Ingress Protection | IP54 |
| Impact Protection | IK10; NEMA 3R |
| Dimensions | |
| Dimension (H*W*D) mm |
2093 * 587 * 314 (without cable management) 2278 * 587 * 314 (5m cable reel) 2701 * 587 * 314 (7m cable reel) |
| User interface | |
| User Interface | 10' HD LCD+ Emergency button (Optional) |
| User Authorization | APP, RFID card, QR code, Credit Card (Optional), PnC, MAC address |
| Language | English, French, German, Italian, Spanish |
| Accessibility | Meets ADA, PAS 1899 Requirements |
| Remote Management | |
| Remote Management | Diagnostics, software updates |
| Certification & Standards | |
| Certification | (CE): CE (NA): CSA, FCC |
| Standard Protocol | IEC 61851-23, ISO 15118-2, DIN 70121 |
| RFID System | ISO 14443 |
Liquid cooling dispenser
| Output | |
| Charging Interfaces | 1* CCS1 / 1* CCS2 / 1* GBT |
| Output DC Voltage Range | 150-1000V DC |
| Maximum DC Current | 500A |
| Cable Lengths | 5m / 7.5m |
| Input | |
| DC Current | Up to 600 A per DC circuit |
| DC Circuits from Power Cabinet | 1 |
| AC Supply | Three-phase AC provided by Power Cabinet |
| Communication with Power Cabinet | Ethernet |
| Operating Conditions | |
| Operating Temperature | -30° to +50° |
| Altitude | < 2500m |
| Storage Temperature | -40° to +50° |
| Humidity | 10% - 95% relative (non-condensing) |
| Installation | Indoor and outdoor |
| Type of Installation | Floor mounted on foundation |
| Ingress Protection | IP54 |
| Impact Protection | IK10; NEMA 3R |
| Dimensions | |
| Dimension (H*W*D) mm |
2093 * 587 * 314 (without cable management) 2278 * 587 * 314 (5m cable reel) 2701 * 587 * 314 (7m cable reel) |
| User interface | |
| User Interface | 10' HD LCD+ Emergency button (Optional) |
| User Authorization | APP, RFID card, QR code, Credit Card (Optional), PnC, MAC address |
| Language | English, French, Germany, Italian, Spanish |
| Accessibility | Meets ADA, PAS 1899 Requirements |
| Remote Management | |
| Remote Management | Diagnostics, software updates |
| Certification & Standards | |
| Certification | (CE): CE (NA): CSA, FCC |
| Standard Protocol | IEC 61851-23, ISO 15118-2, DIN 70121 |
| RFID System | ISO 14443 |
Injet HanYuan Distributed Charging System
Related Blogs
I get this call a lot, usually from someone who’s been managing a depot for a year or two and just can’t figure out why the numbers don’t add up.
How to Scale an EV Fleet Charging Depot Without Rebuilding the Site
As commercial fleets continue their transition to electrification, one challenge often gets overlooked: growth. Many operators begin with a small number of electric vehicles, only to discover that their charging
Most UK fleet managers approach depot electrification the wrong way round. They choose the vehicles first, then scramble to retrofit the charging infrastructure — often discovering, too late, that their
Electric Bus Depot Charging: System Design and Best Practices
As public transport systems transition to electric buses, depot charging infrastructure becomes a critical factor in operational success. Unlike private EV charging, bus fleets operate on strict schedules, making reliable
How to Design EV Charging Infrastructure for Electric Truck Fleets (2026 Guide)
As logistics fleets transition to electrification, one of the biggest challenges is not choosing the vehicle — but building the right charging infrastructure. Unlike passenger EV charging, electric truck fleets
Is Your Charging Hub Leaking Revenue? The Power Island Problem Explained
Experience and feedback from my partners suggest that many Charge Point Operators (CPOs) are unknowingly leaving money on the table. Despite securing high-capacity grid connections and investing in premium distributed
FAQ
What connectors does the dispenser support?
Our dispenser supports CCS1, CCS2, GB/T, and NACS — covering the full range of current EV connector standards, suitable for both passenger cars and commercial vehicles.
What is the maximum output of the dispenser?
The dispenser is available in two cable configurations: the air-cooled version delivers up to 300 A, while the liquid-cooled version reaches up to 600 A for high-capacity EVs and commercial vehicles that demand faster charging.
Is the dispenser easy for drivers to use?
Yes. A 10″ HD touchscreen walks drivers clearly through each step of the session, and the integrated cable management system keeps cables tidy and easy to handle — whether it’s a driver’s first time or their daily routine.
Is the dispenser suitable for outdoor installation?
Yes. The dispenser is rated for both covered and open-air environments. Full IP rating and environmental compliance details are available in the product specification sheet.